<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>NDL</title>
	<atom:link href="http://www.newdelhilab.com/feed" rel="self" type="application/rss+xml" />
	<link>http://www.newdelhilab.com</link>
	<description>Ensuring Power</description>
	<lastBuildDate>Mon, 15 Nov 2010 10:19:49 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Testing Companies</title>
		<link>http://www.newdelhilab.com/testing-companies</link>
		<comments>http://www.newdelhilab.com/testing-companies#comments</comments>
		<pubDate>Tue, 12 Oct 2010 10:53:49 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.newdelhilab.com/?page_id=837</guid>
		<description><![CDATA[]]></description>
			<content:encoded><![CDATA[]]></content:encoded>
			<wfw:commentRss>http://www.newdelhilab.com/testing-companies/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Machinery &amp; Tools</title>
		<link>http://www.newdelhilab.com/machinery-tools</link>
		<comments>http://www.newdelhilab.com/machinery-tools#comments</comments>
		<pubDate>Tue, 12 Oct 2010 10:52:55 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.newdelhilab.com/?page_id=835</guid>
		<description><![CDATA[
Form Fill Seal Machine &#8211; Baba Packaging &#8211; India based manufacturers and suppliers of Automatic Form Fill Seal Machines, Call now to order!
Fruit Juice Processing Machinery &#8211; Sifter International is a leading manufacturer of agro based food processing machines and plants in India. offering a wide range of food, fruit juice and vegetable processing machinery [...]]]></description>
			<content:encoded><![CDATA[<ul>
<li><a href="http://www.babapackaging.net/automatic-form-fill-machine-nitrogen.html">Form Fill Seal Machine</a> &#8211; Baba Packaging &#8211; India based manufacturers and suppliers of Automatic Form Fill Seal Machines, Call now to order!</li>
<li><a href="http://www.sifterinternational.com">Fruit Juice Processing Machinery</a> &#8211; Sifter International is a leading manufacturer of agro based food processing machines and plants in India. offering a wide range of food, fruit juice and vegetable processing machinery of high and reliable quality</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.newdelhilab.com/machinery-tools/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Electrical &amp; Electronic Companies</title>
		<link>http://www.newdelhilab.com/electrical-electronic-companies</link>
		<comments>http://www.newdelhilab.com/electrical-electronic-companies#comments</comments>
		<pubDate>Tue, 12 Oct 2010 10:52:02 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.newdelhilab.com/?page_id=833</guid>
		<description><![CDATA[
Lutron &#8211; Buy lutron lighting control systems. free delivery to uk and eu countries. secure online payment system at the lutron lighting eu online shop.
Turret Punch Press Machine &#124; Punching Machine &#124; Metal Sheet Benders &#8211; Meiban Engineering Technologies solution provide in the field of automobile parts manufacturing, muratec turret punch press, punching metal sheet [...]]]></description>
			<content:encoded><![CDATA[<ul>
<li><a href="http://www.onidserv.com/lutronshop">Lutron</a> &#8211; Buy lutron lighting control systems. free delivery to uk and eu countries. secure online payment system at the lutron lighting eu online shop.</li>
<li><a href="http://www.meibanengg.com">Turret Punch Press Machine | Punching Machine | Metal Sheet Benders</a> &#8211; Meiban Engineering Technologies solution provide in the field of automobile parts manufacturing, muratec turret punch press, punching metal sheet processing, metal sheet benders.</li>
<li><a href="http://www.indodanlampshades.com/lampsbases-brass.html">Brass Lamps</a> &#8211; Indodan Lampshades &#8211; Offering high quality brass lamp shades of attractive shapes and sizes. Brass lamps manufactured at Indodan ensure the long lasting working life</li>
<li><a href="http://www.goldenpeakock.com/cable-blocking-devices.html">Cable Blocking</a> &#8211; Golden Peakock is a preferred manufacturer and supplier of Cable  Blocking Devices, Electrical Wiring Accessories, Brass Components, Lamp  Bases, Display System</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.newdelhilab.com/electrical-electronic-companies/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Invitation For Laboratory Visit</title>
		<link>http://www.newdelhilab.com/invitation</link>
		<comments>http://www.newdelhilab.com/invitation#comments</comments>
		<pubDate>Mon, 08 Mar 2010 15:14:03 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.newdelhilab.com/?page_id=798</guid>
		<description><![CDATA[NDL has decided to invite all interested clients to visit its Testing Laboratory, situated at Bahadurgarh, Haryana. NDL&#8217;s oil testing Laboratory is well equipped and has implemented Quality Management System according to ISO/IEC 17025 &#38; also accredited by NABL. NDL is expertise in &#8220;Transformer conditioning monitoring&#8220;.
NDL believes that visiting laboratory will help its clients to [...]]]></description>
			<content:encoded><![CDATA[<p>NDL has decided to invite all interested clients to visit its Testing Laboratory, situated at Bahadurgarh, Haryana. NDL&#8217;s oil testing Laboratory is well equipped and has implemented Quality Management System according to ISO/IEC 17025 &amp; also accredited by NABL. NDL is expertise in &#8220;<strong>Transformer conditioning monitoring</strong>&#8220;.</p>
<p>NDL believes that visiting laboratory will help its clients to know its Testing procedure better. Each and every client is valuable for NDL and NDL always wish to have healthy, strong and long term business relationship with its clients.</p>
<p>All interested clients kindly drop an email or call before visiting Our Laboratory.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.newdelhilab.com/invitation/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>PCB Analysis</title>
		<link>http://www.newdelhilab.com/pcb-analysis</link>
		<comments>http://www.newdelhilab.com/pcb-analysis#comments</comments>
		<pubDate>Mon, 08 Mar 2010 14:53:11 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.newdelhilab.com/?page_id=781</guid>
		<description><![CDATA[We all are aware that increasing Pollution is the major cause of Global warming. It is our responsibility to work for the prevention of environmental pollution. Industrialization is the major cause so far. Lots of chemicals are being used by every industry on a big scale and those chemicals are flush out into the river, [...]]]></description>
			<content:encoded><![CDATA[<p>We all are aware that increasing Pollution is the major cause of Global warming. It is our responsibility to work for the prevention of environmental pollution. Industrialization is the major cause so far. Lots of chemicals are being used by every industry on a big scale and those chemicals are flush out into the river, spread out into the air and through air and water some where it is harming us.</p>
<p>One of the chemical called PCB (Polychlorinated Biphenyl) was used as liquid dielectric in transformers and capacitors, lubricants and other prior to 1980’s. PCB recognized as a hazardous chemical when it’s dangerous effects were found in environment<strong>. Its’ hazardous effects likes cancer, fertility and other disorders</strong> have been observed and then it was banned after 1985. Stockholm Convention on Persistent Organic Pollutants (POPs) was then created in 2004, in which 158 countries including India have committed for destruction of this toxic chemical like PCB.</p>
<p>It is found that still there are some equipments having quantity of this toxic chemical. In this regard Government of India has ordered Ministry of Environment &amp; Forests (MOEF) to work on it. It is mandatory for every Industry whether it is Electricity Boards, steel manufacturers, Railways, Fertilizer Industries, Paper Industries, Cement or other to go for a PCB analysis or test of their equipments.</p>
<p><strong>Transformer oil samples, capacitors and other can be sent for testing at New Delhi Laboratories Pvt. Ltd.</strong> Your Transformers and capacitors may contain certain levels (ppm) of PCB’s which should be disposed off, More than 50 PPM (Parts per million) means “PCB Contaminated”. We all need to be together and step forward to help out the Government to be successful in this project.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.newdelhilab.com/pcb-analysis/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Power Transformers Testing</title>
		<link>http://www.newdelhilab.com/uncategorized/power-transformers-testing</link>
		<comments>http://www.newdelhilab.com/uncategorized/power-transformers-testing#comments</comments>
		<pubDate>Fri, 08 Jan 2010 06:02:55 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Power Transformers Testing]]></category>

		<guid isPermaLink="false">http://www.newdelhilab.com/?p=733</guid>
		<description><![CDATA[



AMC Package

 » Send Inquiry



Our Power Transformers Testing Includes:

Condition Monitoring-Online
Condition Monitoring-Offline





Condition Monitoring-Online

 » Send Inquiry



Thermography
Thermography is the use of Infrared photography to measure thermal energy from an object. Thermal energy shows us a new picture to us- the one which is not visible with naked eye

Benefits of Infrared Thermography

Prevent -   In one step you can increase [...]]]></description>
			<content:encoded><![CDATA[<table style="width: 400px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="139">
<h2>AMC Package</h2>
</td>
<td width="261"><strong> » <a href="../transformers/inquiry-form#tpt">Send Inquiry</a></strong></td>
</tr>
</tbody>
</table>
<p><strong>Our Power Transformers Testing Includes:</strong></p>
<ul>
<li>Condition Monitoring-Online</li>
<li>Condition Monitoring-Offline</li>
</ul>
<table style="width: 400px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="280">
<h2><a id="cmon" name="cmon"></a>Condition Monitoring-Online</h2>
</td>
<td width="120"><strong> » <a href="../transformers/inquiry-form#tpt">Send Inquiry</a></strong></td>
</tr>
</tbody>
</table>
<p><strong>Thermography</strong></p>
<p>Thermography is the use of Infrared photography to measure thermal energy from an object. Thermal energy shows us a new picture to us- the one which is not visible with naked eye</p>
<p style="text-align: center;"><img title="ir thermo" src="http://newdelhilab.com/wp-content/uploads/2009/07/ir-thermo.jpg" alt="ir thermo" width="386" height="218" /></p>
<p style="text-align: left;"><strong>Benefits of Infrared Thermography</strong></p>
<ul>
<li><strong><span style="text-decoration: underline;">Prevent</span></strong> -   In one step you can increase equipment efficiency and the safety of your facility- a potentially save your company cost of a major electrical malfunction</li>
<li><strong><span style="text-decoration: underline;">Diagnose</span></strong> – by using thermographic photography, we can look inside at the performance of many different systems and make recommendations that will increase the performance of your business</li>
<li><strong><span style="text-decoration: underline;">Repair</span></strong> –   NDL has been providing electrical maintenance and repair since 1990. Safety is our no. 1 priority, so you can assure your electrical work is completed with all the safety standards</li>
</ul>
<h2>Oil Analysis</h2>
<p>Faults can occur at any stage of your transformer’s life and evolve rapidly. Testing your transformers on a regular basis will allow you to detect any unforeseen change in the condition of your transformers.</p>
<p>The recommended tests in this package include:</p>
<ul>
<li>BIS 1866 (8 tests)*</li>
</ul>
<p>*Water Content, Tan Delta, Resistivity, Acidity, IFT, Flash Point, Sludge, Dielectric Strength)</p>
<p><strong>Dissolved Gas Analysis</strong></p>
<p>The use of DGA as a powerful diagnostic tool is a critical and important aspect of determining the condition and health of a transformer.</p>
<p style="text-align: center;"><img style="display: block; margin-left: auto; margin-right: auto;" title="dga" src="http://newdelhilab.com/wp-content/uploads/2009/07/dga2-1024x612.jpg" alt="dga" width="688" height="411" /></p>
<p>D.G.A. is a very reliable and proven techniques to detect the internal faults in working transformers. The fault diagnosis by the gas chromatography is based upon the types &amp; relative quantities of various hydrocarbon gases which can get dissolved in the oil under various fault.<strong> </strong>D.G.A has proved to be reliable means of establishing the healthiness of a transformer which have tripped by suspected mal operation of differential protection (due to charging inrush or C.T Circuit problem) or Buchholz relay (due to air suction or control suction problem) can be returned to service with more confidence on the basis of D.G.A results.<strong> </strong>The accepted methods for performing this test are outlined in the ASTM D3612 and IEC 60567 standards.</p>
<p><strong>Furan Analysis</strong></p>
<p><em><strong>A furan test should be included with yearly maintenance and trends developed to monitor the condition of the paper.</strong></em></p>
<p>Furan Test is used to detect the thermal, oxidative and hydrolytic breakdown of paper insulation. This test, in conjunction with our dissolved fault gas analysis, gives you the best overview of the state of your transformer.</p>
<p>A rough approximation is that, for every 6° to 8° Celsius rise above normal operating temperatures, the life of the insulation is halved. Furans produced from these temperature build-ups are generated in two ways: the first being a localized area of high heat and paper damage, and the second being the general overall heating of the entire insulation system.</p>
<ul>
<li>
<h3 style="font-size: 1.17em;">Early detection of paper insulation breakdown can prevent major damage or outright failure!</h3>
</li>
<li>
<h3 style="font-size: 1.17em;">Inhibitor Content</h3>
</li>
<li>
<h3 style="font-size: 1.17em;">Moisture is destructive to cellulose and even more so in the presence of oxygen.</h3>
</li>
</ul>
<p>Acids are formed that attack the insulation and metals which form soaps and more acids, causing a vicious cycle. Oxygen inhibitor is key element for extending the life of transformers.</p>
<p>The inhibitor currently used is Ditertiary Butyl Para cresol (DBPC). This works similar to a sacrificial anode in grounding circuits; oxygen attacks the inhibitor instead of the cellulose insulation. As this occurs and the transformer ages, the inhibitor is used up and needs to be replaced. Replacement of the inhibitor generally requires that the oil also be treated.</p>
<p><strong> </strong></p>
<p><strong> </strong></p>
<h2 style="text-align: justify;"><strong> </strong>Metals in Oil</h2>
<p>Metals analysis of transformer oil is used to complement dissolved gas analysis (DGA). When a gas-in-oil analysis indicates the presence of a possible fault, metals analysis will help determine the fault type and pinpoint its location<br />
High energy faults not only degrade the transformer’s insulation (oil, paper, wood etc…) but can generate metal particles that will disperse in the oil.</p>
<p>These particles will be distributed throughout the transformer, mainly due to oil circulation. Certain transformer components produce specific metal particles. These metal particles will be found alone or in different combinations depending on the fault type. Establishing the combinations and concentrations of these metal particles will help to narrow the list of components involved in the fault.</p>
<p style="text-align: justify;"><strong>Corrosive Sulphur</strong></p>
<p style="font-size: 1.17em; text-align: justify;"><em>Sulphur, as defined in ASDM D-2864 is “elemental sulphur and thermally unstable compounds in electrical insulating oil, that can cause corrosion of certain transformer metals like copper and sulphur”.</em></p>
<p style="text-align: justify;">Corrosive Sulphur reacts with copper as it comes in contact with it, and does not requires any heat to promote the reaction. It is more pronounced in sealed systems and leads to decomposition of copper-sulphur compound in insulation paper which leads to a weakened dielectric strength</p>
<p style="text-align: center;"><img style="display: block; margin-left: auto; margin-right: auto;" title="corrosiosive sulphur" src="http://newdelhilab.com/wp-content/uploads/2009/07/corrosiosive-sulphur.jpg" alt="corrosiosive sulphur" width="678" height="385" /></p>
<p style="text-align: center;"><em>EFFECT ON COPPER</em></p>
<table style="width: 400px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="280">
<h2><a id="cmof" name="cmof"></a>Condition Monitoring-Offline</h2>
</td>
<td width="120"><strong> » <a href="../transformers/inquiry-form#tpt">Send Inquiry</a></strong></td>
</tr>
</tbody>
</table>
<p style="text-align: justify;"><strong>Frequency Response Analysis</strong></p>
<h4 style="font-size: 1em; text-align: justify;"><em>Frequency Response Analysis is a valuable diagnostic tool for the detection of winding movement and other faults that affect the Transformers impedance.</em></h4>
<p style="text-align: justify;">The Sweep frequency Response Analysis (SFRA) diagnosis is made based on the comparison between two SFRA responses and any significant difference in low frequency region, shift of existing resonance, creation of new resonance, change in shape of plot would potentially indicate mechanical or electrical problem with the winding and core of Transformer.</p>
<p style="text-align: justify;">The frequency response of any form of physical damage to the transformer results in the changes of this RLC network. These changes are what we are looking for and employ frequency response to highlight these small changes in the RLC network within the transformer.</p>
<p style="text-align: justify;"><strong> </strong></p>
<p style="text-align: justify;"><strong>An SFRA analysis permits to predict faults such as:</strong></p>
<ul>
<li>Core fault – Low frequency variation</li>
<li>Shorted turns fault – Low frequency variation</li>
<li>Open circuit or high impedance winding fault – Low frequency variation</li>
<li>Overall radial shift of the winding – Mid frequency variation</li>
<li>Axial shift – Mid to High frequency variation</li>
<li>Core earthing related faults in the transformer/ Tap changer leads &amp; bushing</li>
<li>Leads related faults – High frequency variation</li>
<li>Partial Discharge</li>
</ul>
<p style="text-align: justify;">The electrical stress within the insulation system is never uniform. Material with low dielectric current is more stressed. If the stress increases beyond a limit then a partial insulation failure occurs. Since the discharges occur partially in the insulation system, they are known as partial discharge. Partial Discharge can occur due to the improper design, manufacturing and also the various service conditions.</p>
<h4 style="font-size: 1em; text-align: justify;">So we can say when discharges occur not directly between the electrodes but in the part of insulation system, they are called partial Discharge.</h4>
<p style="text-align: justify;">The transformer insulation is a combination of oil and paper. Occurrence of PD in the transformer produces various problem. In solid insulation, it can create discharge trees, which reduces the insulation strength. In liquid insulation like oil it creates gas bubbles.<strong><br />
</strong></p>
<h2>Tan Delta &amp; Capacitance (Winding &amp; Bushing)</h2>
<p style="text-align: justify;">Every Power electrical appliances in use, undergo stress from Operating Voltage, Mechanical Vibration, Temperature, Gaseous and Solid Metallic Impurities. Under these stress, the degradation of the insulation takes place, in the Electrical equipment. This  stress lead to the continuous ageing of the appliance, with regard to its Electrical Properties. Sometimes there will be an avalanche of Insulation breakdown.  In the total complex network of Power Generation, Transmission, Distribution System ageing of a simple insulation may lead to a disastrous breakdown of the system, causing heavy loss.</p>
<p style="text-align: justify;">To avoid such unexpected breakdowns and for the un-interrupted service, from electrical power  it is very essential to know the insulation quality of the equipment that is going to be used in the power system. And it is also essential to periodically monitor the Insulation property of equipment, that in use in this Power Network.</p>
<h4 style="font-size: 1em; text-align: justify;"><em>In Electrical AC System the Dissipation Factor Tan ? or Power Factor Cos ø is considered as the indicator of quality of insulation.</em></h4>
<p style="text-align: justify;"><strong>Applications</strong></p>
<ul style="text-align: justify;">
<li>Transformers</li>
<li>Generators</li>
<li>CT/CVT</li>
<li>Motors</li>
<li>Breakers</li>
<li>Cables</li>
</ul>
<p style="text-align: justify;"><strong>Insulation Resistance</strong></p>
<p style="text-align: justify;">It is desirable to have Insulation Resistance as high as possible consistent with acceptable mechanical, chemical and heat resisting properties.</p>
<h4 style="font-size: 1em; text-align: justify;"><em>This test is to detect the conductive impurities or mechanical imperfections in the dielectric which affect the quality of insulation which may be developed in the dielectric during the manufacturing process.</em></h4>
<p style="text-align: justify;">The insulation resistance test can detect if this connection is loose. It can also detect whether there are other, undesired and inadvertent, grounds. If the intentional core ground is intact, the resultant resistance should be very low. To check for unintentional core grounds, remove the intentional ground and Megger between the core and the grounded transformer tank. This test should produce very high resistance indicating that an unintentional ground is not present. This test is to supplement DGA that shows generation of hot metal gases (methane, ethane, and ethylene) and to indicate if a spurious, unintentional core ground is the problem. Experience can help locate the source of the problem.</p>
<p style="text-align: justify;"><strong>Polarization Index</strong></p>
<p style="text-align: justify;"><strong> </strong></p>
<p style="text-align: justify;">Polarization Index test that it can provide an indication of insulation quality in ten minutes for very large equipment that might take very long time to get fully charged.</p>
<p style="text-align: justify;"><strong>DC Absorption Test</strong></p>
<p style="text-align: justify;">DC Absorption Test indicates the insulation Condition of the Winding and Supplements to to various other Insulation measurements, therefore, if analyzed, based upon its trend over a period of Time, helps in making decisions better.</p>
<p style="text-align: justify;"><strong>Magnetic Balance</strong></p>
<p style="text-align: justify;"><em>Magnetic Balance Test is performed on transformer to check whether the core and winding of the transformer is in balance position or not. </em>Magnetic Balance is a test of Critical use as it helps us to enhance the efficiency and life of transformers</p>
<p style="text-align: justify;"><strong>Magnetic Current</strong></p>
<p style="text-align: justify;"><em>Magnetic Current Test is performed on transformer to check whether the core and winding of the transformer is in balance position or not. </em>Magnetic Current is a test of Critical use as it helps us to enhance the efficiency and life of transformers.</p>
<p style="text-align: justify;"><strong>Leakage Current</strong></p>
<p style="text-align: justify;">The Leakage Current Test helps us in prediction of Break Down Voltage so as to take the preventive steps well in advance at an early stage of development.</p>
<p style="text-align: justify;"><strong>Excitation Current</strong></p>
<p style="font-size: 1em; text-align: justify;"><em>The purpose of this test is to detect short-circuited turns, poor electrical connections, core de-laminations, core lamination shorts, tap changer problems, and other possible core and winding problems.</em></p>
<p style="text-align: justify;">On three-phase transformers, results are also compared between phases. This test measures current needed to magnetize the core and generate the magnetic field in the windings.<strong> </strong></p>
<p style="text-align: justify;"><strong>Winding Resistance</strong></p>
<p style="font-size: 1em;"><em>Winding resistances are tested in the field to check for loose connections on bushings or tap changers, broken strands, and high contact resistance in tap changers.</em></p>
<p>Results are compared to other phases in wye connected transformers or between pairs of terminals on a delta-connected winding to determine if a resistance is too high. Resistances can also be compared to the original factory measurements or to sister transformers.<strong> </strong></p>
<p style="text-align: justify;"><strong>Turn Ratio</strong></p>
<p style="font-size: 1em;"><em>Turns ratio test performs on transformer to check the voltage ratio between primary and secondary side because the voltage in primary and secondary coil depends on the consequent number of turns in primary and secondary coil.</em></p>
<p>The transformer turns ratio (TTR) test detects shorts between turns of the same coil, which indicates insulation failure between the turns. These tests are performed with the transformer de-energized and may show the necessity for an internal inspection or removal from service.</p>
<table style="width: 400px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="224">
<h2><a id="ovs" name="ovs"></a>Overhauling / Servicing</h2>
</td>
<td width="176"><strong> » <a href="../transformers/inquiry-form#tpt">Send Inquiry</a></strong></td>
</tr>
</tbody>
</table>
<p style="text-align: justify;"><strong>Inspection Stage</strong></p>
<p style="text-align: justify;">A team of our service engineers would visit you, to inspect and analyze the transformers. Inspection helps us to analyze customers requirements and transformers condition so we can plan for the future work which is to be done.</p>
<p style="text-align: justify;"><strong>Overhauling Procedures</strong></p>
<p style="text-align: justify;">After the inspection and based upon the measured data, suitable course of Overhauling Procedure is recommended to improve the reliability &amp; the Life of equipment. However, at least once in a decade, overhauling is essential to restore the health of equipment.</p>
<p style="text-align: justify;"><strong>Commissioning Stage</strong></p>
<p style="text-align: justify;">All the Chemical &amp; Electrical Tests are performed before commissioning of the equipment to ensure the. Integrity  and for obtaining the future reference values.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.newdelhilab.com/uncategorized/power-transformers-testing/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Transformer Oil Analysis</title>
		<link>http://www.newdelhilab.com/uncategorized/transformer-oil-analysis</link>
		<comments>http://www.newdelhilab.com/uncategorized/transformer-oil-analysis#comments</comments>
		<pubDate>Fri, 08 Jan 2010 06:00:52 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Transformer Oil Analysis]]></category>

		<guid isPermaLink="false">http://www.newdelhilab.com/?p=730</guid>
		<description><![CDATA[



Emergency Testing

 » Send Inquiry




IN CASE OF EMERGENCY CALL: +91 9899792718 / 12
In case of emergency, NDL offers same day emergency DGA testing. We make sure you get the results you need within the shortest possible time frame.




Transformer Signature

 » Send Inquiry



 
Establish the time-zero condition of your transformer with our Signature package.
The recommended Transformer [...]]]></description>
			<content:encoded><![CDATA[<table style="width: 411px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="211">
<h2>Emergency Testing</h2>
</td>
<td width="200"><strong> » <a href="../transformers/inquiry-form#toa">Send Inquiry</a></strong></td>
</tr>
</tbody>
</table>
<p><img title="oil analysis alert" src="../wp-content/uploads/2009/07/oil-analysis-alert.jpg" alt="oil analysis alert" width="61" height="52" /></p>
<p><span style="color: #c0010c;"><em><strong>IN CASE OF EMERGENCY CALL:</strong></em></span> +91 9899792718 / 12</p>
<p>In case of emergency, NDL offers same day emergency DGA testing. We make sure you get the results you need within the shortest possible time frame.</p>
<table style="width: 411px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="241">
<h2><a id="ts" name="ts"></a>Transformer Signature</h2>
</td>
<td width="170"><strong> » <a href="../transformers/inquiry-form#toa">Send Inquiry</a></strong></td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<p><strong>Establish the time-zero condition of your transformer with our </strong><strong><em>Signature</em> package.</strong></p>
<p>The recommended <strong>Transformer oil tests</strong> in this package include:</p>
<ul>
<li>Dissolved Gas Analysis</li>
<li>Water content</li>
<li>Furan in oil</li>
<li>Inhibitor Content</li>
<li>ASTM package</li>
<li>PCB analysis</li>
<li>Power Factor 27°C and 90°C</li>
</ul>
<p><strong> </strong></p>
<table style="width: 411px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="232">
<h2><a id="fd" name="fd"></a>Fault Determination</h2>
</td>
<td width="179"><strong> » <a href="../transformers/inquiry-form#toa">Send Inquiry</a></strong></td>
</tr>
</tbody>
</table>
<p>This basic package is the first step when trying to locate and identify a specific transformer problem. The results from these <strong>Transformer oil tests </strong>allow you to determine what other tests need to be performed in order to have a clear understanding of your transformer’s actual condition.</p>
<p>The recommended tests in this package include:</p>
<ul>
<li>Dissolved Gas Analysis</li>
<li>Furan content</li>
<li>Water content</li>
<li>Metals in Oil</li>
</ul>
<p><strong> </strong></p>
<table style="width: 470px; height: 38px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="189">
<h2><a id="rt" name="rt"></a>Routine Test</h2>
</td>
<td width="222"><strong> » <a href="../transformers/inquiry-form#toa">Send Inquiry</a></strong></td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<p>It is recommended to perform routine tests at least once a year in order to monitor the health of your transformers. Faults can occur at any stage of your transformer’s life and evolve rapidly. Testing your transformers on a regular basis will allow you to detect any unforeseen change in the condition of your transformers.</p>
<p>The recommended tests in this package include:</p>
<ul>
<li>Dissolved Gas Analysis</li>
<li>Furan Content</li>
<li>BIS 1866 (8 tests)*</li>
</ul>
<p>*Water Content, Tan Delta, Resistivity, Acidity, IFT, Flash Point, Sludge, Dielectric Strength</p>
<table style="width: 411px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="218">
<h2><a id="fa" name="fa"></a>Factory Acceptance</h2>
</td>
<td width="193"><strong> » <a href="../transformers/inquiry-form#toa">Send Inquiry</a></strong></td>
</tr>
</tbody>
</table>
<p>Throughout our two decades of existence, NDL has provided sub-ppm Dissolved Gas Analysis (DGA) services to most major transformer manufacturers in the world. When ordering a new transformer, specify NDL for heat run DGA test results.</p>
<p>The text below can be inserted in the appropriate clause of your specifications for new, refurbished or repaired transformers:</p>
<p><strong>FACTORY TEST RESULTS</strong></p>
<p>The appropriate low level Dissolved Gas Analyses (DGA) for this transformer shall be performed during heat run factory tests. All Transformer oil analysis tests  shall be performed by New Delhi Laboratories from Delhi, India.</p>
<table style="width: 411px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="224">
<h2><a id="pc" name="pc"></a>Pre Commissioning</h2>
</td>
<td width="187"><strong> » <a href="../transformers/inquiry-form#toa">Send Inquiry</a></strong></td>
</tr>
</tbody>
</table>
<p>When a new transformer is commissioned, NDL recommends that the following test package be performed immediately.</p>
<p>The recommended tests in this package include:</p>
<ul>
<li>Dissolved Gas Analysis</li>
<li>ASTM Package</li>
<li>Oxidation Inhibitor</li>
<li>Water content</li>
<li>Power Factor 27°C and 90°C</li>
<li>Furan Content</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.newdelhilab.com/uncategorized/transformer-oil-analysis/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Tan Delta &amp; Capacitance</title>
		<link>http://www.newdelhilab.com/uncategorized/tan-delta-capacitance</link>
		<comments>http://www.newdelhilab.com/uncategorized/tan-delta-capacitance#comments</comments>
		<pubDate>Fri, 08 Jan 2010 05:33:12 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[Tan Delta & Capacitance]]></category>

		<guid isPermaLink="false">http://www.newdelhilab.com/?p=728</guid>
		<description><![CDATA[Tan Delta &#38; Capacitance
Every Power electrical appliances in use, undergo stress from Operating Voltage, Mechanical Vibration, Temperature, Gaseous and Solid Metallic Impurities. Under these stress, the degradation of the insulation takes place, in the Electrical equipment. This  stress lead to the continuous ageing of the appliance, with regard to its Electrical Properties. Sometimes there will [...]]]></description>
			<content:encoded><![CDATA[<p>Tan Delta &amp; Capacitance</p>
<p>Every Power electrical appliances in use, undergo stress from Operating Voltage, Mechanical Vibration, Temperature, Gaseous and Solid Metallic Impurities. Under these stress, the degradation of the insulation takes place, in the Electrical equipment. This  stress lead to the continuous ageing of the appliance, with regard to its Electrical Properties. Sometimes there will be an avalanche of Insulation breakdown.  In the total complex network of Power Generation, Transmission, Distribution System ageing of a simple insulation may lead to a disastrous breakdown of the system, causing heavy loss.</p>
<p>To avoid such unexpected breakdowns and for the un-interrupted service, from electrical power  it is very essential to know the insulation quality of the equipment that is going to be used in the power system. And it is also essential to periodically monitor the Insulation property of equipment, that in use in this Power Network.<br />
In Electrical AC System the Dissipation Factor Tan ? or Power Factor Cos ø is considered as the indicator of quality of insulation.<br />
Applications</p>
<p>* Transformers<br />
* Generators<br />
* CT/CVT<br />
* Motors<br />
* Breakers<br />
* Cables</p>
]]></content:encoded>
			<wfw:commentRss>http://www.newdelhilab.com/uncategorized/tan-delta-capacitance/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Sitemap</title>
		<link>http://www.newdelhilab.com/sitemap</link>
		<comments>http://www.newdelhilab.com/sitemap#comments</comments>
		<pubDate>Thu, 07 Jan 2010 09:29:48 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.newdelhilab.com/?page_id=698</guid>
		<description><![CDATA[
Home 

About Us
Services
Inquiry
Client Login
Contact Us




Services 

Transformer Services

Transformer Oil Analysis
Transformer Oil Qualification
Power Transformer Testing
Power Distribution Transformers
Aged 15+ Yrs Transformers
Tap Changer (OLTC)


Sub Stations 

CT
CVT &#38; VT
Breakers
Generators &#38; Motors
Cables
Lightening Arrestors
Earthing
Substation Thermography
Relays  Calibration




Tan Delta &#38; Capacitance
Transformer Infrared Thermography
Transformer Overhauling




Tests
Products
Training
News
Credentials

]]></description>
			<content:encoded><![CDATA[<ul type="disc">
<li><strong><a href="http://www.newdelhilab.com/">Home </a></strong>
<ul style="font-size: 16px;" type="square">
<li><strong><a href="http://www.newdelhilab.com/about">About Us</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/transformers">Services</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/inquiry-form">Inquiry</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/collaborate/">Client Login</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/contact-us">Contact Us</a></strong></li>
</ul>
</li>
</ul>
<ul type="disc">
<li><strong><a href="http://www.newdelhilab.com/about">Services </a></strong>
<ul type="square">
<li style="font-size: 16px;"><strong><a href="http://www.newdelhilab.com/transformers">Transformer Services</a></strong>
<ul type="circle">
<li style="font-size: 16px;"><strong><a href="http://www.newdelhilab.com/transformers/oil-analysis">Transformer Oil Analysis</a></strong></li>
<li style="font-size: 16px;"><strong><a href="http://www.newdelhilab.com/transformers/oil-qualification">Transformer Oil Qualification</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/transformers/power-transformers">Power Transformer Testing</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/transformers/distribution-transformers">Power Distribution Transformers</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/transformers/aged-15yrs-transformers">Aged 15+ Yrs Transformers</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/transformers/tap-changer-oltc">Tap Changer (OLTC)</a></strong></li>
</ul>
</li>
<li><strong><a href="http://www.newdelhilab.com/sub-stations">Sub Stations </a></strong>
<ul style="font-size: 16px;" type="circle">
<li><strong><a href="http://www.newdelhilab.com/sub-stations/ct">CT</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/sub-stations/cvt-vt">CVT &amp; VT</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/sub-stations/breakers">Breakers</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/sub-stations/generators-motors">Generators &amp; Motors</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/sub-stations/cables">Cables</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/sub-stations/lightening-arrestors">Lightening Arrestors</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/sub-stations/earthing">Earthing</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/sub-stations/substation-thermography">Substation Thermography</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/sub-stations/relays-calibration">Relays  Calibration</a></strong></li>
</ul>
</li>
</ul>
<ul style="font-size: 16px;" type="square">
<li><strong><a href="http://www.newdelhilab.com/tan-delta-capacitance">Tan Delta &amp; Capacitance</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/infrared-thermography">Transformer Infrared Thermography</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/overhauling">Transformer Overhauling</a></strong></li>
</ul>
</li>
</ul>
<ul style="font-size: 16px;" type="disc">
<li><strong><a href="http://www.newdelhilab.com/tests">Tests</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/products">Products</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/training">Training</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/news">News</a></strong></li>
<li><strong><a href="http://www.newdelhilab.com/client-testimonials">Credentials</a></strong></li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.newdelhilab.com/sitemap/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Resources</title>
		<link>http://www.newdelhilab.com/resources</link>
		<comments>http://www.newdelhilab.com/resources#comments</comments>
		<pubDate>Mon, 31 Aug 2009 14:45:29 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.newdelhilab.com/?page_id=588</guid>
		<description><![CDATA[RESOURCES
NDL is an NABL accredited Laboratory providing all types of Transformer services in India. NDL is expert in Transformer oil testing and also providing Transformer maintenance and repair jobs.
Categories
Electrical &#38; Electronic Companies &#160;&#160;&#160;&#160;&#160;&#160;&#160;Other Testing Companies 
Machinery &#38; Tools
If you are interested in reciprocal linking you can send us email at imarketing@newdelhilab.com with your Site URL [...]]]></description>
			<content:encoded><![CDATA[<p><strong>RESOURCES</strong></p>
<p>NDL is an NABL accredited Laboratory providing all types of Transformer services in India. NDL is expert in Transformer oil testing and also providing Transformer maintenance and repair jobs.</p>
<p><strong>Categories</strong></p>
<p><a href="http://www.newdelhilab.com/electrical-electronic-companies"><strong>Electrical &amp; Electronic Companies</strong></a> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<a href="http://www.newdelhilab.com/testing-companies"><strong>Other Testing Companies</strong> </a></p>
<p><a href="http://www.newdelhilab.com/machinery-tools"><strong>Machinery &amp; Tools</strong></a></p>
<p>If you are interested in reciprocal linking you can send us email at <a href="mailto:imarketing@newdelhilab.com">imarketing@newdelhilab.com</a> with your Site URL and Description</p>
<p>Please use the following description of our website to link in your website.</p>
<p><strong>Title:</strong> Transformer maintenance<br />
<strong>Description:</strong> NDL providing Transformer maintenance services throughout India. We are expertise in Dehydration Filtration, Transformer Overhauling and Tan Delta &amp; Capacitance services.<br />
<strong>URL:</strong> <a href="../">http://www.newdelhilab.com</a></p>
<p><strong>‘OR’</strong></p>
<p><strong>Title:</strong> Transformer Testing<br />
<strong>Description:</strong> NABL accredited Laboratory providing all types of Transformer Testing services. It is one of the leading companies in India. Get relevant and accurate oil testing results generated by our testing experts.<br />
<strong>URL:</strong> <a href="../">http://www.newdelhilab.com</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.newdelhilab.com/resources/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

